Basic maintenance of optical fiber welding machine,
by:Tumtec
2021-01-15
Optical fiber welding machine, 2016 - the basic maintenance
07 -
04 1, V groove, and fixture clean please prepare pure alcohol (
The purity in 99.
More than 5%)
And the V groove cleaning brush or close not fluff cotton sticks.
V groove is arranged naked fiber precision dominant parts, bare fiber fixture is neat fiber press V groove in medium voltage.
V groove or clamp platen even attached to a small amount of dust or coated particles, can contribute to an optical axis, properly in place.
1.
1 V groove V groove of cleaning and use glue alcohol cleaning brush (
Cotton bar)
From the electrode side lateral sweep V groove.
Dust, is likely to fall to the microscope head so clean, please make sure to outside cleaning.
1.
2 fixture clean on glue alcohol cotton sticks full wipe the bare fiber fixture.
With dry cotton swab to wipe the same place, to remove excess alcohol.
Note: blow bag is defiled electrode bar, do not used for optical fiber welding machinery very clean.
2, clean the goggles please prepare pure alcohol (
The purity in 99.
More than 5%)
Not fluff cotton swab and tight.
Wind cover within the protection of the lens is not clean, will produce a shadow or lower lighting levels, resulting in welding machine can't normal succeeded.
1.
1 with the purity in 99.
More than 5% alcohol cotton sticks gently wipe the lens surface clean.
Finally, with dry cotton swab to wipe, to remove excess alcohol.
。
1.
2 serious alcohol swab to clean the dust, please replace the attached new protection glasses.
3, the electrode stick replacement to ensure the quality of connection, usually recommended for electrode rods in about 1000 times be replaced after discharge.
If continue to use, increase after the loss of welding and welding strength.
3.
Validation is using the electrode discharge number 3.
2 before changing electrode, waiting for the machine after reset, cut off the power supply south, unplug the power cord.
3.
Three electrodes with the hand knob screw rod fixed unscrewing, remove the electrode plate.
3.
4 remove the old electrode.
3.
5 new electrode stick before installation, please use glue alcohol gauze cleaning electrode rod.
3.
6 plastic parts with electrode rods, electrodes rod into the slot.
3.
7 gently tighten the knob screw.
3.
After 8 electrode rods to replace, please for electrode rod ageing operation (
Air discharge)
And zero discharge times.
4, clean microscope lens around in the assignments section V groove between two observations in the optical fiber with a microscope.
Microscope lens attached dust, can cause optical testing is not accurate, not a good connection.
4.
1 cut off power supply, open the wind cover.
4.
2 remove the front electrode, microscope lens can emerge.
4.
3 gently with sticky cotton stick with a small amount of alcohol to wipe the lens.
From the lens center to outside wipe the rim to the lens in spiral way.
Then, with dry cotton swab to excess alcohol wipe to go to pay attention to don't leave a stain on the lens.
4.
4 screw electrode stick, in order to avoid the position offset, please discharge experiment was carried out.
5, clean 5 fiber cutting knife and rotating cutting blade Angle.
1 if the cutter blade, rubber gasket, or anvil block become dirty, may cause the loss of cutting quality and make the fiber surface or surface become dirty, which resulted in increased splicing loss.
With glue alcohol swab to clean the cutting blade, rubber gasket, anvil block.
5.
If the cutter blade wear or damage, even clean the blade can reduce the quality of the optical fiber end face, the blade should be not wear location in to the next.
Recommend replacing electrode in the same time interval to the position of the rotary blade.
5.
2.
1 with precision flat head screwdriver to unscrew the retaining screw, the width of the screwdriver should not be more than 2.
5mm。
5.
2.
2 will be the next digital rotate to the highest point, then tighten the screw.
6, battery (
Battery)
Nimh batteries to charge and discharge if they have enough power to charge, because the memory effect will reduce battery capacity.
As this occurs, perform the function of the battery discharge to the remaining power reduced to 0, and then back to the battery to recover capacity.
Suggest you to perform a complete discharge each month.