Speak with authority, quality is trustworthy.

Optical fiber welding machine simple failure analysis and elimination

by:Tumtec     2021-01-21

simple fault analysis and ruled out

1, the welding machine in welding process shows 'can't find the fiber or fiber surface is not clean'.

this is mainly caused by the pollution of surface of the optical system, should be cleaned with anhydrous alcohol protection glass ( Located just below the electrode) And at the same time clean fiber cover the lens. After wait for alcohol dry and then to weld. If the fault can't be ruled out, the machine need maintenance repair service center.

2, welding machine in welding process to show 'fiber migration is too big.

the main cause of this situation is caused by the V groove groove with dirt, need to clean the V groove. Clean in the anhydrous alcohol to clean, can use toothpick or high pressure within the tank on stolen goods to clean air, pay attention to, not with hard objects to clean operation of V groove, so easy to cause damage of V groove.

if after cleaning can't eliminate 'fiber migration is too large, the drive recovery, also can't repair, artificial regulation requires repair service center.

3, fiber found in welding process, welding part is unusual, electrode discharge is not uniform.

this is mainly due to the tip of the electrode was oxidized, because of the existence of tip with oxide electrode made uniform discharge units, welding quality is bad. Need to clean the electrode.

if not normal discharge after cleaning, you need to replace the electrodes. In general, the electrodes in welding need to clean the electrode 1000 times or so, in the use of the 3000 or so you will need to replace the new electrode. When replacing electrode electrode, please use the original factory use other can't guarantee the normal work of the function of welding electrodes, it might damage the welding machine.

4, prompt replacement electrode welding machine.

this is due to set up a reminder to replace electrode welding machine Settings, please clean the electrode when prompted to replace electrodes, at the same time, can enter the welding machine parameter Settings in the changes of the parameters. Standards set for 3000 times.

5, battery life, reduce the

welding machine battery and mobile phone battery, need to pay attention to using method, under normal circumstances, the battery capacity is above 30%, please use the battery power supply. Please note that at the same time, in the use of alternating current power supply, will be for the welding machine battery charging. After found that battery life, can be three times the depth of the charge and discharge the battery, so the time of the battery can be extended.

once found the battery fast charge, and shorter working hours, please to three times the depth of the charge and discharge, if cannot be ruled out fault, indicates that the battery life to the limit, need to replace the original rechargeable battery, replace the battery, please contact the service center.

6 welding machine, battery power supply mode can't boot up.

in, please ensure that the battery is connected to the power adapter before starting to normal, if the connection is normal circumstances are still unable to boot, you need to repair repair service center