Optical fiber welding machine problems and correct treatment!
by:Tumtec
2020-05-12
Optical fiber welding machine problems and correct treatment!
Warning messages (
English message are shown in brackets)
Because treatment method of fiber placement left error (
LFPC)
Left fiber cutting length is short.
Left optical fiber into the V groove part was broken.
The center of the optical fiber is not left V groove.
Left propulsion motor wiring problem.
1.
To determine if the wrong 1, 2, please cut again on the left side of the optical fiber, and ensure the cutting length.
2.
To determine if the error of 3, then again placed on the left side of the optical fiber.
3.
If after 1, 2, 3, false, do the
System self-check 】
, if still cannot solve the fault, please contact with after-sales service department.
Right fiber placement error (
RFPC)
Right fiber cutting length is short.
Optical fiber into the right part of V groove has been broken.
Fiber have no right into the center of the V groove.
Right propulsion motor wiring problem.
Left fiber analogs error handling solutions for optical fiber on the right side.
About optical fiber placement error (
LRFPC)
Same as above.
Left fiber analogs error processing method to handle on both sides of the fiber.
Left fiber is unqualified,
LFNQ)
Optical fiber surface with ash left.
Left fiber cutting quality is poorer, defects of existing fiber core and cladding fiber damage, incomplete phenomenon, etc.
1.
To determine if the wrong one, please use alcohol to clean on the left side of the optical fiber.
2.
To determine if an error 2, please make again for welding optical fiber.
Optical fiber is unqualified (right
RFNQ)
Right of fiber surface dust.
Right fiber cutting quality is poorer, defects of existing fiber core and cladding fiber damage, incomplete phenomenon, etc.
Left fiber analogs error handling solutions for optical fiber on the right side.
Optical fiber is unqualified (right
LRFNQ)
Same as above.
Left fiber analogs error processing method to handle on both sides of the fiber.